| Features | A special design duplex filter for separating solids and/or aerosols (liquid content) from gases using a patented double block and bleed main transfer valve. This is intended for applications using high pressures and/or dangerous gas compositions, to ensure maximum operator safety. |
|---|---|
| Flange Connection | ASME or DIN ¾” – 8” or DN 20 – DN 200 |
| Filter element | Fiberglass/stainless steel disposable cartridges* Option available for preliminary separation using demister, cyclone, or cyclone demister all within the same housing |
| Grade of filtration | 0,1 µm - 250 µm |
| Operating pressure | >500 bar (size and temperature dependent) |
| Filter housing | - carbon steel (St 45-8 / A106B) - stainless steel (1.4404 / 316L) - non-welded |
| General Accessories and Special Equipment | 1.) Connecting elements Flexible connection possibilities e.g., flanged, NPT, weld-on ends, ball valves, needle valves 2.) Instruments Differential pressure connections such as optical and optical/electrical differential pressure measurement systems 3.) Materials Filters available on request in Duplex or Super Duplex 4.) Optional equipment Cover lifting/pivoting mechanism Cover safety device |
| Special accessories for gas filtering | Pre-separator for liquid reduction / cyclone and cyclone demister In addition to standard, filters also available in Duplex and Superduplex (on request) Liquid level switches Magnetic level indicator Bulls Eyes Adaptable fluid reservoir for saving the separated fluid |
The BOLLFILTER duplex filter type BFD-C/P DBB consists of two filter chambers. One filter chamber is in operation while the other is being cleaned or on stand-by. If contamination exceeds a tolerance threshold, the unit can switch over to the clean filter side - by means of the Double Block and Bleed method - without any pulse pressure. The contaminated filter element is then cleaned while operation continues.